How do I order fire partition profiles and get a quotation?
Send your plans, panel elevations, detail drawings, required quantities and delivery destination. Please also specify whether you need profiles, accessories or a complete partition proposal. Glazing, finish and supply scope affect pricing; we quote against the agreed drawings and item list.
What is the visible frame width and finished wall thickness?
The five published Class A and Class C galvanized steel section drawings each show a 50 mm face width. Section depth varies by configuration. Finished wall thickness also depends on the glazing, installation details and design requirements; check the selected section and project details together.
How thick are the steel frame components?
Across the five published sections, the drawn frame core and pressure plate are 1.5 mm thick, and the glazing bead is 1.2 mm. Where a cover plate is shown, it is 1.0 mm thick. Refer to the original drawing for component positions, glazing and section dimensions of the selected model.
Can you provide fire test documentation?
Ask our sales team for test documentation covering your proposed assembly. Check the glazing, frame, sealing materials, installation method and scope stated in the report. A profile or glass specification alone does not establish the fire performance of a complete partition.
What is the typical lead time?
Smaller and mid-sized projects are generally scheduled for 7–10 days. Projects over 1,000 m² are generally scheduled for 15–20 days. The actual lead time depends on the models, quantities, colours and production schedule and should be agreed when the order is confirmed.
How are freight cost and transit time determined?
Freight depends on profile weight, packing, destination and carrier route. Share the delivery address and estimated quantity so shipping cost and estimated transit time can be included in the quotation. Final arrival depends on dispatch and carrier updates.
Which profile colours are available?
Black, grey and white are standard colour options. Ask our sales team about other colours, and confirm the sample, finish requirements and lead time before ordering.
How do I request a fire door quotation?
Provide the opening dimensions, design requirements, door handing, leaf configuration and hardware needs. Fire door pricing depends on the selected construction and supply scope; our sales team will review the drawings and requirements before quoting.