| Configuration | Frame section | Glazing as drawn | Original drawing |
|---|---|---|---|
| Class A · Double glazing | 50 × 115 mm | 25 mm composite glass + 6 mm tempered glass | Download PDF |
| Class A · Side glazing | 50 × 106 mm | 25 mm composite glass | Download PDF |
| Class C · Single glazing | 50 × 82 mm | 12 mm tempered glass | Download PDF |
| Class C · Double glazing | 50 × 98 mm | 6 mm + 6 mm tempered glass | Download PDF |
| Class C · Side glazing | 50 × 106 mm | 12 mm tempered glass | Download PDF |
Dimensions are transcribed from the supplied section drawings and apply only to the illustrated configurations. They do not state the fire performance of a complete partition.
Match the drawing to the product
Check the Class A or Class C designation, single or double glazing, and whether the glass sits centrally or to one side of the frame. Dimensions and thicknesses apply to the configuration shown in that drawing. Check similarly named products individually.
Separate section dimensions from material thickness
Frame section dimensions, core thickness, pressure plate thickness and glass thickness describe different features. Follow dimension lines and callouts to the relevant components, then compare them with site openings, panel layouts and edge details. A section drawing does not define the overall wall dimensions.
Review drawings and performance documents separately
A section drawing explains component positions and assembly details. For performance verification, review test documentation that covers the supplied configuration, including the glazing, profiles, sealing materials and installation conditions. A drawing does not replace a test report.